Mennekes | Amedio - Configuration for ChargePilot

Before starting the configuration, please check the charger firmware version complies with the latest compatible firmware version.

Please follow the instructions in ebee - Configuration for ChargePilot

Addtional or deviating steps are listed below

Connection to the charger

Login credentials

Username: operator
Password: aquired from the customer

Other charger settings

Fallback settings

Fallback works only with the FW version ≥ 5.33.x

  1. Navigate to Load Management Local

  2. Enable Disconnected Upper Limit for SmartCharging: Disable

image-20240304-161609-20240319-165200.png

MeterValueSampleInterval (if not 4s)

Configuration of the MeterValues interval for the connector 2 (This step should still be done maually within the current FW version)

  • Option 1: Add the envvar MeterValueSampleInterval_2 = 4s in Balena

  • Option 2: Open the webinterface of the connector 2, change the field “Meter Value Sample Interval (OCPP)” to 4s