Kempower - Configuration for ChargePilot

Before starting the configuration, please check the charger firmware version complies with the latest compatible firmware version.

Connection to the charger

Charger connection

Connect to the charger cloud web portal

Login Data:
The charger can only be configured in Kempower’s portal (ChargeEye). The access to the portal needs to be applied via the ticket system.

Network settings

Ethernet

  • Use the single port on the front side (9).
    The Switch on the backside is only for the satellites

  • Mode for Ethernet configuration: DHCP

Schematischer Aufbau PowerUnit (Hub).png

OCPP settings

Backend

  • Connection type: Ethernet

  • OCPP Mode: OCPP-J 1.6

  • OCPP Backend URL: ws://172.22.0.1:9000

ChargeBox ID

  • Serial number of the charger by default or according to the installation protocol

Other charger settings

Authorization settings

  • Navigate to the Authorization tab

  • Configure the Parameters as follows:

    • Authorization required to charge: true

    • Wait for authorization: true

    • RFID identification in use: true

Autocharge/Free charging settings

When this function is activated, charger starts transaction either with the identifier predefined in the charger, or with the EV MAC address (Plug & Charge).

  • Navigate to the Authorization tab

  • Configure the Parameters as follows:

    • Authorization required to charge: true

    • Wait for authorization: true

    • AutoCharge identification in use: true

Satellite configuration

(for the charger model C802P160ND8)